VX40 Series
The VX40 series general-purpose drives feature a powerful 32-bit microcontroller and open-loop operation, making them suitable for a wide range of industrial applications. Speed control is available in SVC and SVPWM modes, with the capability to control asynchronous motors without an encoder. These drives are produced in a wide power range from 2.2 kW to 500 kW.
- 33 years of manufacturing experience.
- An annual production capacity of 40,000 units.
- The largest drive manufacturer in the Middle East.
- Certified as a Knowledge-Based Company by the Vice-Presidency for Science and Technology.
- CE Certificate of the European Community.
- Standard Modbus Communication
- Built-in PID
- 16-Step Speed Control Function and Mathematical Functions for Two Speed References A and B
- Torque Functions, Simple PLC, and PID Control
- Digital inputs with activation capability of +24 V or 24 V (COM) and support for two-wire and three-wire control functions.
- Pump Control System Function for Up to Two Motors
- Programmable Delay for Activation or Deactivation of Digital Inputs and Outputs
- Fault Protection for Overcurrent, Overvoltage, Undervoltage, Temperature, and Overload with Detailed Fault Information
- Built-in DC Braking, Flux Braking, and Dynamic Braking up to 30 kW
- Various Functions: Linear, 2nd Order, 1/3, 1/7, and Four-Step Broken-Line Curve (V/F Curve) in SVPWM Mode
- Plastic Injection Card Installation Capability
| Performance | Specifications |
|---|---|
| Input Voltage (V) | 380V AC 3PH (-15% ~+10%) |
| Input Frequency (Hz) | 47-63Hz |
| Output Voltage (V) | 0 to Rated Input Voltage |
| Output Frequency (Hz) | 0-400Hz |
| Control Mode | SVC و SVPWM |
| Speed Regulation Accuracy | SVC 1:200 |
| Overload Capacity | 150% of Rated Current for 1 Minute 180% of Rated Current for 10 Seconds |
| Speed Control Accuracy | <20mV |
| Speed Fluctuations | <2ms |
| Analog Input / Output (I/O) | Two Analog Inputs (0–10 V or 0–20 mA) / Two Analog Outputs (0–10 V or 0–20 mA) |
| Digital Input / Output (I/O) | Eight Common I/O Inputs, Two Programmable Relay Outputs, One Transistor Output, and One Pulse Input/Output |
| Network Communication | RS485: Modbus Protocol |
| Mountable | Wall-Mountable, Flanged (for Specific Power Ratings) |
| Operating Ambient Temperature | 10°C ~ 50°C – (Above 40°C, the device power decreases by 1% for each 1°C increase.) |
| Cooling | Air Cooling with Fan |
| Protection Functions | Overcurrent, Overvoltage, Undervoltage, Overtemperature, Overload, etc. |